Lennox 63W26 Two-Stage Ignition Control Board

0 out of 5

$830.30

Lennox 63W26 2 Stage Ignition Control Board.
Use with Lennox Furnace Models G60DF-36A-070X-07, G60DF-36A-070X-09, G60DF-36B-090-07, G60DF-36B-090-09, G60DF-48C-110-09, G60UH-24A-070-09, G60UH-24A-070-10, G60UH-36A-070X-10, G60UH-36B-090-10, G60UH-36C-110-09, G60UH-36C-110-10, G60UH-48B-090-10, G60UH-48B-090X-10, G60UH-48C-110-09, G60UH-48C-110-10, G60UH-60C-110X-08, G60UH-60C-110X-1G60UH-60D-135-07, G60UH-60D-135-08, G60UH-60D-135-1,G61MP-36B-045-09, G61MP-36B-070-09, G61MP-36B-071-07, G61MP-48C-090-08 09, G61MP-48C-110-07 08, G61MP-60C-090-07, G61MP-60C-091-08, G61MP-60C-111-08

Replaces 23W25, 23W2501, 63W2601, 100869-01, 100869-02, 100869-03

Size: 8-3/16" x 4-3/16"
Line Voltage: Line 120V (97-132 VAC), 50/60 Hz
Current Draw: 0.5A Input Current, Plus Valve Load @ 24VAC
Igniter Current: 1.0A Resistive @ 95 VAC Output
Prepurge: 5 Seconds
HSI Warmup: 20 Seconds
Trial for Ignition: 4 Seconds
Postpurge: 5 Seconds
Interpurge: 15 Seconds
Auto Restart Delay: 60 Minutes (After Soft Lockout)
Ignition Trials: Five, Four Retries If Flame Is Not Sensed On The First Trial•Second Stage Recognition Delay: 30 Seconds (Only On First Call For High Fire On A Call For Heat)
Second Stage ON Delay: 10 Or 15 Minutes (Depending On Dip Switch S1 Setting For Switch 2) When Used With A Single-Stage Thermostat•Second Stage Fan OFF Delay: 30 Seconds
Flame Failure Response Time: 2 Seconds Maximum @ 1A
LEDs: Two LEDs Provide The Following: A Red LED Provides System Status And Faults, A Green LED Shows Information About The EnviraCOM Traffic
Heat Fan ON Delay: 45 Seconds
Heat Fan OFF Delay: 60, 90, 120 or 180 Seconds (Depending On Dip Switch S1 Settings For Switches 3 And 4)
ool Fan ON Delay: 2 Seconds
Cool Fan OFF Delay: 2 Or 45 Seconds (Depending On Dip Switch S1 Setting For Switch 5)
Gas Control: Any VAC Redundant, Direct Ignition Gas Control Rated At 1.5A Or Less. Honeywell VR8205 Recommended
Cooling Contactor: Any 24 Vac Contactor Rated At 1.0A Or Less
Induced Draft Blower: 2.2 FLA/25LRA Maximum @ 120VAC
Circulator Load: 14.5FLA/25LRA Maximum @ 120VAC

Availability: 1 in stock SKU: 63W26 Category: Brand: