Robertshaw 780-845 Universal Ignition Control Module
$299.73
Robertshaw 780-845 Direct Spark/Intermittent Pilot Non-Integrated Spark Ignition Modules.
When the thermostat calls for heat, the 780-845 control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established.
The 780-845 lockout ignition control provides 90 seconds of spark, followed by a 6 minute time delay (purge) between ignition attempts. After three tries, if no pilot flame is sensed, the control goes into a one-hour lockout period. At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition
Specifications
Input Voltage: 24 VAC to 50/60 Hz
Transformer: 24 VAC / 20 VA
Safety lockout timing: 90 seconds
Spark rate: 4 to 15 sparks per second
Pilot valve, Main valve: 1 amp at .5 PF
Combined load: 1.5 at .4 PF
Flame sense current: .7 mA DC @ 25°C / 24 VAC
Maximum total current load: 1.5 amp
Flame failure reignition time: 2 seconds maximum
Ambient temperature rating: –40 to 175° (–40 to 80°C)
Relative humidity: 95% noncondensing at 104°F
- Used in Models
This product is not used in any models.